dc.description.abstractIntroduction: Postoperative pain and swelling are the unfavourable sequalae of endodontic treatment if debris produced while instrumentation gets expulsed beyond periapex. The amount of debris varies with every different instrumentation technique and design characteristics. Among the various advanced technologies and instruments available as of today are the thermal treated alloys and also the offset centre of mass. Examples of these designs are PTG & PTN respectively. In-vitro studies reported PTN expulses less debris than PTG. Nonetheless, in clinical scenario’s, the periapex tissues could act as natural barrier, the response may be affected due to hosts immunity response. Therefore, the aim of the study is to evaluate and compare post-operative pain following single visit endodontic treatment using PTN & PTG rotary file systems.en_US
dc.language.isoenen_US
dc.publisherK.L.E. Academy of Higher Education & Research, Belagavien_US
dc.subjectPostoperative pain, ProTaper Gold, ProTaper Next, Single visit endodontics.en_US
dc.titleComparative evaluation of post - operative pain after single visit endodontic treatment using protaper next and protaper gold rotary file systems: a randomized clinical trialen_US
dc.typeDissertationsen_US
Appears in Collections:Conservative Dentistry & Endodontics

Files in This Item:
File Description SizeFormat 
IE0218002 Dr.Chaitra Suresh Bakare.pdf1.31 MBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.